Catalog | Video |
Execution standard: GB/T 7551-1997 Certificate (eqv OIML R60) Combined error: 0.015% Sealed to IEC 529: Protection grade: IP67 or IP68. Protection against total immersion in water for 30 minutes at a pressure corresponding to a 1 m head of water. |
|
Dimensions
(In mm. 1mm = 0.03937 inches)
CAP./SIZE |
A |
B |
C |
D |
E |
F |
G |
10~25klb |
36.6 |
49.3 |
222.2 |
190.5 |
20.6 |
41.1 |
50.5 |
35klb |
38.1 |
63.5 |
222.2 |
190.5 |
20.6 |
41.1 |
64.8 |
50~75klb |
62 |
74.7 |
393.7 |
292.1 |
33.3 |
82.5 |
75.9 |
100klb |
74.7 |
100.1 |
469.9 |
381.0 |
41.4 |
82.5 |
107.9 |
Circuit Diagram:
Electrical Termination
4 Core cable standard lengths:
<=35klbs: 6.0 m, >=50klbs: 12.0m
Diameter: Φ6
Connection: Refer to the following drawing:
Notice:
Do not change the length of cable, or lese, it will effect the sensitivity of load cell.
Specification
Item Parameter |
C3 |
Unit |
Rated load (Emax): |
10,20,25,35,50,75,100 |
klbs |
Maximal numbers of load cell verification Intervals (Nlc): |
3000 |
d |
Minimum load cell verification intervals Intervals ( Vmin): |
0.01 |
% of rated load |
Rated output (Cn): |
2.0±0.1% |
mV/V |
Combined error: |
0.015 |
-% of rated output |
Temperature effect on sensitivity(Tkc): |
0.0012 |
=% of rated output/ |
Temperature effect on zero balance(Tk0): |
0.0008 |
-% of rated output |
Zero balance: |
1.0 |
-% of rated output |
Input resistance(Rlc): |
775±5 |
Ω(Ohms) |
Output resistance(Ro): |
702±2 |
Ω(Ohms) |
Insulation resistance: |
≥5000 |
MΩ (Mega-Ohms) |
Safe overload: |
150 |
% of rated capability |
Ultimate overload: |
300 |
% of rated capability |
Operating temperature range: |
-20~+70/-20~+160 |
℃/ °F |
Recommend excitation: |
8~15 |
V( DC or AC) |
Maximum excitation: |
24 |
V( DC or AC) |
Material of elastomer: |
Alloy steel / Stainless steel |
|
Protection class: |
IP67/IP68 |
Hotline.
Mr. Tuyên - 0904883061
TƯ VẤN CÔNG NGHỆ : |
Mr. Nguyễn Ngọc Tuyên |
Giám đốc điều hành - CEO |